| Material
Safety Data Sheet
May be used to comply with OSHA's Hazard Communication Standard, 29 CFR 1910.1200. Standard must be consulted for specific requirements. |
U.S.
Department of Labor
Occupational Safety and Health Administration (Non-Mandatory Form) Form Approved OMB No. 1218-0072 |
![]() |
|
IDENTITY (As Used on Label and List) Carbide Taps |
Note: Blank spaces are not permitted. If any item is not applicable, or no information is available, the space must be marked to indicate that. |
|
Manufacturer's Name |
Emergency
Telephone Number (727) 848-1811 |
| Address (Number, Street, City, State, and ZIP Code) | Telephone
Number for Information (727) 848-1811 |
| 6622 Industrial Ave | Date
Prepared August 08, 2001 |
| Port Richey Florida, 34668 | Signature of Preparer (optional) |
| Hazardous Components (Specific Chemical Identity; Common Name(s)) | OSHA PELL | ACGIH TLV | Other Limits Recommended | %(optional) |
| TUNGSTEN CARBIDE | ||||
| (LIMITS FOR TUNGSTEN DUST) | *5 mg/m |
41-97
|
||
| COBALT | 0.1 mg/m | *0.1 mg/m |
3-97
|
|
| TANTALUM | ||||
| (LIMITS FOR TANTALUM DUST) | 5 mg/m | *5 mg/m |
0-52
|
|
| VANADIUM CARBIDE |
-
|
*-
|
0-5
|
|
| * depends on Grade Specification | ||||
| Boiling Point | N/A | Specific Gravity (H2O = 1) |
11.0-15.5
|
| Vapor Pressure (mm Hg) | N/A | Melting Point | - |
| Vapor Density (AIR = 1) | N/A | Evaporation Rate(Butyl Acetate = 1) | N/A |
| Solubility in Water - INSOLUBLE | |||
| Appearance and Odor - Dark Gray Metal/No Odor | |||
| Flash Point (Method Used) N/A | Flammable Limits - N/A | LEL - | UEL - |
| Extinguishing Media - For powder fires, smother with dry sand, dry dolomite, ABC extinguisher, or flood with water | |||
| Special Fire Fighting Procedures - Powder Fire, confined to small area, use respirator approved for toxic dusts and fumes. Large Fire, Fire fighter should use self-contained breathing apparatus. | |||
| Unusual Fire and Explosion Hazards - Dust may present fire or explosion hazard under rate favoring conditions or particle size, dispersion and strong ignition source. However, this is not expected to be a problem under normal conditions. | |||
| (Reproduce locally) | OSHA 174, Sept. 1985 |
| Stability- Stable | Conditions to Avoid - N/A | ||
| Incompatibility (Materials to Avoid) - Contact with dust oxidizers may cause fire and explosion. | |||
| Hazardous Decomposition or Byproducts - N/A | |||
| Hazardous Polymenzation -Will Not Occur | Conditions to Avoid - N/A | ||
| Route(s) of Exposure: Grinding Cemented carbide product will produce dust of potentially hazardous ingredients which can be inhaled swallowed or come in contact with the skin or eyes. | |||
| Health Hazards (Acute and Chronic): It is reported that cobalt dust is the most probable cause of such respiratory diseases. Symptoms include productive cough, wheezing, shortness of breath, chest tightness and weight loss. Interstitial fibrosis (lung scarring) can lead to permanent disability or death. Certain pulmonary conditions may be aggravated by exposure. | |||
| Carcinogenic Assessment: (NPT Annual Report, IRAC Monograms, other): None of the components of this material have been identified as known or suspect carcinogens by NPT, IRAC, or OSHA. | |||
| Effects of Overexposure: Inhalation: Dust from grinding can cause irritation of the nose and it also has the potential for causing Transient or permanent respiratory diseases, including occupational asthma and interstitial fibrosis, in a small percentage of exposed individual | |||
|
Medical Conditions Generally Aggravated by
Exposure: Skin contact: can cause irritation or an allergic
skin rash due to cobalt sensitization. Certain skin conditions such
as dry skin, may be aggravated by exposure. |
|||
|
Emergency and First Aid Procedures -
Inhalation: If symptoms of pulmonary
involvement develop (Coughing, wheezing, etc.), remove from exposure
and seek medical attention.
|
|||
| Steps to Be Taken in Case Material is Released or Spilled - Ventilate area of spill. Clean up using methods which avoid dust generation such as vacuum (with appropriate filter to prevent airborne dust levels which exceed the PEL or TVL). wet dust mop or wet clean up. If airborne dust is generated use an appropriate NIOSH approved respirator. |
| Waste Disposal Method - Dispose of in accordance with appropriate government regulations. May be sold as scrap for reclaim. |
| Precautions to Be taken in Handling - Maintain good housekeeping procedures to prevent dust accumulation during grinding. Avoid dust inhalation and dire skin contact with the dust. Do not strike product with hardened steel hammer or similar device because of possible fracture/shattering of product. Product should be pressed if inserted into another metal part or product. |
| Other Precautions: Clean up using methods which avoid dust generation such as vacuum (with appropriate filter to prevent airborne dust levels which exceed the PEL or TVL) wet dust mop or wet clean up. If airborne dust is generated use an appropriate NIOSH approved respirator. |
| Respiratory Protection(Specify Type) Use an appropriate NIOSH approved respirator if airborne dust concentrations exceed appropriate PEL or TLV. All appropriate requirements set forth in 29 CFR 1910.134 should be met. | ||
| Ventilation - Use local exhaust ventilation which is adequate do not exceed the PEL or TLV. If such equipment is not available, respirators as specified above. | ||
| Protective Gloves - Protective gloves or Barrier cream are recommended when contact with dust or mist is likely. Prior to applying the barrier cream or protective gloves, wash thoroughly. | Eye Protection - Safety glasses with side shields or goggles should be worn. | |
| Work/Hygenic Practices - Wash hands thoroughly after handling, before eating or smoking. Wash exposed skin at the end of work shift. Do not shake clothing, rags or other items to remove dust. Dust should be removed by washing or vacuuming. | ||
| * U.S.G.P.O.: 1986 - 491 - 529/45775 |